Home | Produits | EU868 LoRaWAN Temperature sensor – Dual PT1000 contact probes

EU868 LoRaWAN Temperature sensor – Dual PT1000 contact probes

Reference : TX TEMP CONT2 600-232

  • EU868 LoRaWAN compatible device
  • Double temperature measurement with PT1000 probes
  • Temperature measurement range from -180°C to +250°C
  • 2m cable length
  • Very long radio range
  • Up to 15 years of autonomy
  • Replaceable battery

Applications of the Temperature sensor with dual PT1000 probes

The temperature sensor is equipped with two external PT1000 contact probes, allowing temperature measurement on contact surfaces. The PT1000 probes provided with the sensor allow measurement of extreme temperatures ranging from -180°C to +250°C.

This LoRa(WAN) sensor is particularly suitable for measuring the temperature of domestic hot water loops (DHW). The two PT1000 probes allow simultaneous measurement of the forward and return temperatures of the DHW circuit. Thus, the LoRa temperature sensor with double contact probes allows to prevent the risk of legionella development.

The rugged temperature sensor can be used in LoRaWAN mode or in Enless proprietary LoRa mode for simplified integration into your BMS. Learn more.

The autonomy of the rugged temperature sensor can last up to 15 years, thanks to a high-capacity D-type battery.

Technical Specifications

Protocol : EU868 LoRaWAN
Dimensions : L 118 x H 79 x W 43 mm
Enclosure IP rating : ABS IP 65
Type of probes : 2x PT1000 contact probes
Probes' cable length : 2m
Contact probes measurement range : - 180°C / +250°C
Probes' accuracy : +/- 0,5°C
Probes' resolution : 0,01°C
Transmission interval : 15mn by default
Power supply : Replaceable D 3.6V Lithium battery
Battery autonomy : Up to 15 years
Configuration / Installation : Radio
Status LEDs : 3 LEDs
Certifications : CE & UKCA

Easily process temperature sensor data on your BMS using our Modbus or BACnet receivers.

Our proprietary LoRa receivers natively decode data from our LoRa sensors, saving you valuable integration time if you intend to process the data on an PLC or a BMS. Available in Modbus or BACnet versions, the receivers will convert Enless sensor data into Modbus tables or BACnet objects.

Access proprietary LoRa receivers.

Related products

Contact

Let’s discuss your projects together !

    *Required information

    I accept the general terms and conditions of use. Your data is collected and processed in accordance with our personal data policy. More information